Folder Breakout Boards
Flush mounting Breakout Boards designed to fit popular industry standard drives. Created to eliminate additional panel space and wiring terminations. Please contact us for further details.
Categories
Folder FCBB-15-16 Breakout Board
Part Number: FCBB-15-16; LIST PRICE: $ 88.00 US Dollars
The FCBB-15-16 is ideal for feedback cables that need to be run through conduit or seal tight and terminated at the drive. This eliminates additional panel space or wiring terminations, and allows feedback wires to be terminated directly on the CN2 connector. The FCBB-15-16 features protective molding on both sides with screw terminal signal descriptions and pin numbers for the CN2 connector.
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current: 5 Amps
Wire Capacity: (UL) 30-16 AWG
Screw Terminals: (CSA) 28-16 AWG
L x W x H: 1.25” x 1.25” x .75”
Testing: 100% Cirrus Signature 1000
Manufactured using UL Rated Materials
Folder FCBB-44-12 Breakout Board
Part Number: FCBB-44-12; LIST PRICE: $88.00 US Dollars
Ultra 3000/5000 I/O Breakout Board for use on Allen Bradley® Type Servo Drives with the SERCOS interface.
The FCBB-44-12 eliminates additional panel space and wiring terminations, allowing field wiring to be terminated directly on the CN1 connector via screw terminals. The FCBB-44-12 features protective molding on both sides along with screw terminal signal descriptions and pin numbers for the CN1 connections.
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current: 5 Amps
Wire Capacity: (UL/CUL) 30-14 AWG
Screw Terminals: (CSA) 28-14 AWG
L x W x H: 2.5” x 1.06” x .75”
Testing: 100% Cirrus Signature 1000
Folder FCBB-44-44 Breakout Board
Part Number: FCBB-44-44; LIST PRICE: $96.00 US Dollars
For use on Ultra3000 and Ultra3000i Drives, the FCBB-44-44 eliminates additional panel space and wiring terminations.
The FCBB-44-44 eliminates additional panel space and wiring terminations, allowing field wiring to be terminated directly on the CN1 connector via screw terminals. The FCBB-44-44 features protective molding on both sides along with screw terminal signal descriptions and pin numbers for the CN1 connections.
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current: 5 Amps
Wire Capacity: (UL/CUL) 30-16 AWG
Screw Terminals: (CSA) 28-16 AWG
Dimensions: 3.06”L x 1.75”W x 1.0”H
Testing: 100% Cirrus Signature 1000
Folder FCBB-K2K-44-22 Breakout Board
Part Number: FCBB-K2K-44-22 List Price $92.00
I/O break-out board allows field connections to the I/O terminals of the Allen Bradley® Kinetix 2000 Drive
The FCBB-K2K-44-22 eliminates additional panel space and wiring terminations, allowing field wiring to be terminated directly on the IOD/AF connector via screw terminals. The FCBB-K2K-44-22 features protective molding on both sides along with screw terminal signal descriptions and pin numbers for the most commonly used connections.
Folder FCBB-K3C-50-42 Breakout Board
Part Number: FCBB-K3C-50-42; LIST PRICE $97.00 US Dollars
K3C Breakout Board for use on Kinetix 300/350 Drives. Eliminates additional panel space and wiring terminations. Use this breakout board with a FCBB-15-16 feedback board to fully outfit a Kinetix 300/350 drive.
Eliminates additional panel space and wiring terminations.
Connects directly to:
- 50 pos. I/O Connector
- Protective Moldings
- Pin Numbers on each screw terminal
- High quality terminal blocks
- Manufactured using UL Rated materials
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current: 5 Amps
Wire Capacity: (UL/CUL) 30-16 AWG
Screw Terminals: (CSA) 28-16 AWG
LxWxH: 2.25” x 1.7” x .875”
Testing: 100% Cirrus Signature 1000
Folder FCBB-K6K2 Breakout Board
Part Number: FCBB-K6K2; LIST PRICE: $104.00 US Dollars
FCBB-K6K-2 Breakout Board, for use on Kinetix 6000 & 7000 drives. Eliminates additional panel space and wiring terminations.
Eliminates additional panel space and wiring terminations.
Connects directly to :
- I/O (IOD) Connector.
- Motor Feedback (MF) Connector.
- Shielded housing and protective moldings.
- Pin numbers on each screw terminal.
- High quality Phoenix terminal blocks.
- Manufactured using UL Rated materials.
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current: 5 Amps
Wire Capacity: (UL/CUL) 30-16 AWG
Screw Terminals: (CSA) 28-16 AWG
L x W x H: 3.25” x 2” x 1.094”
Testing: 100% Cirrus Signature 1000
Folder FCBB-K6K3 Breakout Board
Part Number: FCBB-K6K3; LIST PRICE: $157.28 US Dollars
K6K-3 Breakout Board for use on Kinetix 6000 & 7000 drives. Eliminates additional panel space and wiring terminations.
Eliminates additional panel space and wiring terminations.
Connects directly to :
- I/O (IOD) Connector.
- Motor Feedback (MF) Connector.
- Auxiliary Feedback (AF) Connector.
- Shielded housing and protective moldings.
- Pin numbers on each screw terminal.
- High quality Phoenix terminal blocks.
- Manufactured using UL Rated materials.
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current: 5 Amps
Wire Capacity: (UL/CUL) 30-16 AWG
Screw Terminals: (CSA) 28-16 AWG
L x W x H: 3.25” x 2.75” x 1.094”
Testing: 100% Cirrus Signature 1000
Folder FCBB-K6XC-59-76 Breakout Board
Part Number: FCBB-K6XC-59-76 LIST PRICE: $241.40 US DOLLARS
For use on Kinetix 6200/6500 Drives providing I/O, Encoder, Aux. Encoder & Safe-Off connections.
The FCBB-K6XC-59-76 Break-Out Board provides the necessary terminal block connectors to attach the Encoder, Aux. Encoder and I/O as well as the Cascading Safety Connections. The FCBB-K6XC-59-76 connects directly to the front of the drive and provides cable exiting towards the bottom or back of the enclosure. Encoder, Aux. Encoder & I/O and “Safe-Off” connections each have their own cable connector on the break-out board making it easier to wire and troubleshoot.
In addition, a front mounting “Safe-Off” interconnect cable is provided with each Break-Out Board to connect to the next drive module. Each cable is polarized providing correct connections, module to module.
Cable shield clamps are provide on each cable connector with dual position capability which enables the cables to exit the module either downwards or towards the rear of the drive.
NOTE: 2 MODULES ARE SHOWN ONLY TO ILLUSTRATE THE “SAFE OFF” MODULE TO MODULE CABLES.
TECHNICAL SPECIFICATIONS:
Max. Voltage: 30VDC
Max. Current, Terminal Blocks: 5 Amps
Max. Current, “Safe-Off” Connector: 1.5 Amps
Wire Capacity: 24 – 16 AWG
L x W x H: 10” x 2.125” x 2”
Testing: 100% “CableScan” Automatic Tester
Folder FCBB-M9-16 9 pin Breakout Board
Part Number: FCBB-M9-16; List Price TBD
The FCBB-M9-16 is for networking the Allen-Bradley Ultra 3000/5000 Servo Drives.
The FCBB-M9-16 allows communication cable wiring when multiple Ultra Drives are networked together. It accomplishes this by allowing pass-through wiring from drive to drive.